QF Series
High Temperature Use
This gage has a polyimide carrier backing for excellent performance at high temperatures. It offers a small gage length of 0.2 or 0.4mm, for use as a stress concentration measurement gage or shear stress measurement gage.
| Main Test Materials | Metal,Ceramic | Materials Backing | Polyimide |
| Operating Temperature | -20 to +200°C | Materials Element | Cu-Ni alloy foil |
| Compensation range | +10 to +100°C | Strain limit | 3% (30000×10-6) |
| Bonding adhesive | NP-50 CN,C-1 |
Fatigue life at room temp. | 1×106 (±1500×10-6) |
| Gage pattern | Type | Gage length (mm) |
Gage width (mm) |
Backing length (mm) |
Backing width (mm) |
Resistance (ohms) |
| QFLG-02-11 | 0.2 | 1.4 | 3.5 | 2.5 | 120 | |
2-wire Polyimide leadwire attached 5cm long |
QFBX-04-11-005LE | 0.4 | 1.3 | 5.4 | 1 | 120 |
2-wire Polyimide leadwire attached 5cm long |
QFBY-06-11-005LE | 0.6 | 0.8 | 5.3 | 1 | 120 |
2-wire Polyimide leadwire attached 2cm long |
QFLX-1-11-002LE | 1 | 1.3 | 5 | 2 | 120 |
| QFLK-1-11 | 1 | 0.7 | 4.5 | 1.4 | 120 | |
| QFLK-2-11 | 2 | 0.9 | 5.5 | 1.5 | 120 | |
| QFLA-1-11 | 1 | 1.3 | 5 | 2.5 | 120 | |
| QFLA-2-11 | 2 | 1.5 | 6.5 | 3 | 120 | |
| QFLA-3-11 | 3 | 1.7 | 8.8 | 3.5 | 120 | |
| QFLA-5-11 | 5 | 1.5 | 10 | 3 | 120 | |
| QFLA-6-11 | 6 | 2.2 | 12.5 | 4.3 | 120 | |
| QFLA-1350-11 | 1 | 2 | 5 | 4 | 350 | |
| QFLA-2350-11 | 2 | 1.9 | 6.1 | 3.5 | 350 | |
| QFLA-3350-11 | 3 | 3.2 | 8.5 | 5 | 350 | |
| QFLA-6350-11 | 6 | 2.6 | 12.5 | 4.5 | 350 | |
| QFLA-61000-11 | 6 | 4.6 | 13.5 | 7 | 1000 |
| Gage pattern | Type | Gage length (mm) |
Gage width (mm) |
Backing length (mm) |
Backing width (mm) |
Resistance (Ω) |
| QFCA-1-11 | 1 | 1.3 | 7.2 | 7.2 | 120 | |
| QFCA-3-11 | 3 | 1.7 | 11 | 11 | 120 | |
| QFCB-2-11 | 2 | 1.5 | 8.2 | 8 | 120 |
| Gage pattern | Type | Gage length (mm) |
Gage width (mm) |
Backing length (mm) |
Backing width (mm) |
Resistance (Ω) |
| QFRA-1-11 | 1 | 1.3 | 7.2 | 7.2 | 120 | |
| 3 | 1.7 | 11 | 11 | 120 |