PM/PMF Series
Mold Gage

This gage has been specially designed for measuring interior strain in concrete and mortar under a loading test. The PM is sealed between thin resin plates, and the PMF employs super engineering plastics capable of superior water-proofing characteristics.

Main Test Materials Concrete
Mortar
Materials Backing Acrylic(PM)
Special plastics(PMF)
Operating Temperature -20 to +60°C Materials Element Cu-Ni alloy wire(PM)
Cu-Ni alloy foil (PMF)
Compensation range - Strain limit 2%
(20000×10-6)
Bonding adhesive - Fatigue life at room temp. -

[ SERIES "PM" ]

  • Single element(G.F. 2.1 approx.)
  • 0.3mm2 heat resistive vinyl leadwire 2m pre-attached
    Total resistance per meter : 0.12(Ω)

    Type Gage
    length
    (mm)
    Gage
    width
    (mm)
    Backing
    length
    a(mm)
    Backing
    width
    b(mm)
    Backing
    thickness
    c(mm)
    d(mm) Resistance
    (Ω)
    PML-60-2L 60 1 125 13 5 40 120
    PML-120-2L 120 1 180 13 5 65 120

    PML gages with pre-attached lead wire of 3-wire system are available on request.

    [ SERIES "PMF" ]

  • Single element(G.F. 2.0 approx.)Quarter bridge with 3-wire system
  • 0.09mm2 3-wire paralleled vinyl leadwire 2m pre-attached
    Total resistance per meter : 0.4(Ω)

    Type Gage length
    (mm)
    a
    (mm)
    b
    (mm)
    c
    (mm)
    d
    (mm)
    Resistance
    (Ω)
    PMFL-50-2LT 50 60 ø8 ø4 27 120
    PMFL-60-2LT 60 70 ø8 ø4 32 120

    Temperature integrated PMF gages are available on request.

    Texas Measurements, Inc | College Station, Texas | +1 979.764.0442