Strain Gage Transducers Instruments Special Instruments Strain gage

 



 

Gage series
Applicable specimen
Normal operational temperature range
(°C)
Compensated temperature range
(°C)
Description
General purpose foil gages
F series
Metal
Glass
Ceramics
-20 to +80
+10 to +80
General purpose, stress concentration, torque, etc.
General purpose foil, higher temperature
UF series
Metal -20 to +150 +10 to +100 Usable up to 150°C
Polyester backing integral lead wire foil gage
PF series
Metal
Mortar
-20 to +80 +10 to +80 A gage with preattached lead wire
General purpose, longer gage lengths
PF series
Metal
Mortar
-20 to +80 +10 to +80 For metal and mortar
General purpose, longer gage lengths
P series
Concrete
Mortar
-20 to +80 +10 to +80 For concrete and mortar
Waterproofed and integral leadwires
WF series
Metal 0 to +80 +10 to +80 Integral lead wire gage with waterproof coating of epoxy resin
Combined strain & temperature measurement
FLA-T series
Metal
Glass
Ceramics
-20 to +80 +10 to +80 Thermocouple is integrated. Simultaneous strain and temperature measurement using TML data logger.
Metal backed/waterproof for
concrete surface
FLM/WFLM series
Concrete
Mortar
-20 to +80 +10 to +80 Used for concrete surface. WFLM is a waterproof type.
Magnetic field use
MF series
Metal
Concrete
-20 to +80 - Available with twisted or shielded lead wire
Concrete embedment
PM/PMF series
Concrete
Mortar
-20 to +60 - Embedded in concrete or mortar for loading test on concrete or mortar
High elongation, post yield
YEF/YF series
Metal -20 to +80 - Large strain measurement up to 10 to 20%
Wood, sheetrock, low modulus
materials
LF series
Wood
Gypsum
-20 to +80 +10 to +50 Foil gages for low elastic modulus materials
Wood, sheetrock, low modulus
materials
L series
Wood
Gypsum
-20 to +50 +10 to +50 Having longer gage length than that of LF series
Plastics
GF series
Plastics -20 to +80 +10 to +80 Temperature compensated for acrylic or epoxy resin
Composites
BF series
Composite material -20 to +200 +10 to +80 For composite materials such as carbon glass fiber
Low temperature to -196 °C
CF series
Metal
Ceramics
-196 to +80 -196 to +80 Usable down to -196 °C
High temperature to +200 °C
QF series
Metal
Ceramics
-20 to +200 +10 to +100 Usable up to 200°C
High temperature to +300 °C
ZF series
Metal
Ceramics
-20 to +300 +10 to +100 Usable up to 300°C
Special purpose chevron pattern
SF series
Metal -20 to +200 +10 to +100 Measures stress in the gage axis directly
Wedable, woterproof, high
temperature to 600 °C
AW series
Metal -196 to +650 +10 to +600 Installed by spot welding
Special purpose bolt gage
BTM
Bolt M10 or larger -10 to +80 - Embedded in a pre-drilled hole of a bolt for axial strain measurement
Special mechanical/waterproof
protection
FTP series
Metal -20 to +80 +10 to +80 Gages with water and mechanical protection
Special purpose one sided
gage
DD series
Metal -10 to +70 - Separated measurement of bending and axial strains of a plate
Crack propagation measurement
FAC series
Metal -20 to +80 - Measures length of crack. Exclusive adapter is required.
Temperature measurement
TF series
All materials -20 to +200 - Installed in the same manner as a strain gage and used for temperature measurement

Site Map: Strain Gages, Strain Gage Series List, Integral Lead Wire Option, Strain Gage Adhesives, Coating Materials, Connection Terminals, Strain Gage Coding System, Theory of Strain Gages, Strain Gage Connections and Bridge Circuits, Load Cells, Displacement Tranducers, Pressure Transducers, Acceleration Transducers, Data Loggers/Static Strain meters, Dynamic Strainmeters, Histrogram Recorder, Indicators, Special Instrumentation, Related Instrumentation